Command Start CS-580i FM Spécifications Page 36

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 77
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 35
If the Auto operation mode is selected, the operation mode will be judged by set temperature on remote
control, intake air temperature and outdoor air temperature.
During operating mode judgement, indoor fan runs at low fan speed and outdoor fan runs in the purpose
of detecting the intake air temperature and outdoor air temperature (for 20 seconds)
HEAT COOL DRY
0
1
2
3
T3
4
36
28
27
26
25
24
23
22
21
20
19
18
17
16
T1
T2
0
1
2
3
13 19 21 23 25
Outdoor Air Temp
Set Temp
Set Temp on
Remote Control
T1 T2 T3
16,17,18
19,20,21,22
23,24,25,26
27,28,29,30
+10
+8
+7
+6
-3
-3
-3
-3
-5
-7
-7
-8
If the operation mode changed, T1, T2, T3 will change as follow:
Heating Cooling /Soft Dry Operation: +2
Cooling /Soft Dry Heating Operation: -2
5
Set Temp=Remote Set Temp + T
8.6 Automatic Operation
36
CS-PE9DKE / CU-PE9DKE / CS-PE12DKE / CU-PE12DKE
Vue de la page 35